Nov-21 Page 13 of 132 59812-K001 Rev 10
significantly over the years and oil mist detection techniques have improved substantially to maintain
adequate protection.
The Graviner Mk 6 OMD provides the following benefits:
Multi engine capability, up to 8 engines on a single system
Suitable for both 2 stroke and 4 stroke engines.
Elimination of sample pipes - reduced installation costs.
Significant reduction in scanning time - 1 .2 seconds for a system of 64 Detectors.
Relocating system controls and display to the safety and comfort of control room.
Figure 3 Graviner Mk6 OMD Components
1.2 DESCRIPTION
The system comprises three main components (refer to Figure 3):
Detectors 1-E3561-301 (with base)
1- E3561-301-01 (Short sample pipe)
1-D5622-001 (replacement detector head)
Control Panel 1-53836-K170 (Bulkhead Mounting)
1-53836-K206 (Flush Mounting)
Engine Junction Boxes 1-D4720-001-XX (20mm Power & Comms
Connections)
1-53836-K224-XX (25mm Power & Comms
Connections)
And connecting cables
Junction Box to Detector cable (Straight) 1-43682-K108-XX
Junction Box to Detector cable (Right Angle) 1-43682-K109-XX
The Graviner Mk6 OMD system can comprise up to 64 detectors directly mounted on the crankcases of
up to 8 engines, allowing both main propulsion and auxiliary generators to be monitored at the same
time.