Nov-21 Page 83 of 132 59812-K001 Rev 10
Figure 119 Isolate Detector
Select ISO to isolate the detector, preventing the reporting of alarms or faults. The Isolate and Detector
Select DE-ISO to de-isolate the detector and return it to normal operation.
4.1.3 Isolate Relay
Select 3. Relay
Figure 120 Isolate Relay Engine Selection
Select the required engine from the list.
Figure 121 Isolate Relay
Select ISOLATE to isolate the relay, preventing operation in the event of an alarm or DE-ISOLATE to
return the relay to normal operation.
4.2 SYSTEM MONITORING
The OMD Mk6 provides access to a range of system parameters that can be used to monitor system
operation and can also give an early indication of changes in the engine.
Engine Status, see section 3.4.
Provides an indication of engine faults and isolations as well as the maximum average oil mist level
measured on the engine.
Detector Screen, see section 3.7.
Provides an indication of the detector deviation alarm level, faults and isolations as well as the peak oil
mist levels measured on the detector.