Detector  See section 3.7 
Status  Allows the panel Configuration to be reset to the default state. 
3.10.1  Erase Configuration 
Select 3. Status 
 
Figure 110  Erase Configuration 
Select 1. Erase Configuration 
 
Figure 111  Confirm Configuration Reset. 
Confirm the configuration is to be erased. The panel configuration will revert to the factory default. 
Default Configuration 
Engines  1 
Detectors  4 
Average Alarm   0.7mg/l 
Deviation Alarm   0.3mg/l 
 
 
 
 
 
 
 
3.11  ALARM OPERATION 
3.11.1  Action on Alarm 
On receipt of either a Deviation or Average alarm the engine should, unless connected to a Slowdown / 
Shutdown relay, be stopped if safe to do so and allowed to cool down so that the background oil mist 
levels reduce before entering the engine room. Investigations can then be carried out to identify and 
rectify the cause of the alarm. Once the fault in the engine has been rectified the OMD system can be re-
set and the display returns to the normal mode.