Nov-21 Page 15 of 132 59812-K001 Rev 10
Junction Box
Enclosure Rating IP65
Max detector inputs 14
Fuse Rating 4A 20mm slow blow
Back-up alarm relay Volt-free change over contacts rated at 30Vdc 1A
Power Consumption 100mW
Temperature Rating 0 70
o
C
Dimensions
Height 186mm (110mm mounting centres)
Width 318mm (240mm mounting centres)
Depth 90mm
Weight 2.7kg
Control Panel
Enclosure Rating IP32
Material Steel
Max detector inputs 64
Max engines 8
Output Relays Volt-free change over contacts rated at 30Vdc 1A
Relay contact minimum wetting current = 10mA
Main Alarm 1 set (energised during normal operation)
Fault Alarm 1 set (energised during normal operation)
Engine Slow/Shutdown Alarm 8 sets, 1 set per engine (de-energised during normal operation)
Alarm Ranges
Deviation Alarm 0.05mg/l to 0.5mg/l (adjustable) (Default 0.3mg/l)
Average Alarm 0.3mg/l to 1.3mg/l (adjustable) (Default 0.7mg/l)
Backup Alarm 1.6mg/l (fixed)
Operating Voltage 24Vdc (+30% -25%)
Power Consumption 5.2W
Operating Temperature Rating 0 to 70
o
C
Storage Temperature Rating -20
o
C to 60
o
C
Dimensions
Bulkhead Mounted
Height 313mm (270mm mounting centres)
Width 500mm (445mm mounting centres)
Depth 118mm
Flush Mounted