Nov-21 Page 86 of 132 59812-K001 Rev 10
Figure 123 Emulsified oil in the detector base
Fuel in the lube oil (a green colour in the lube oil) may indicate a problem with the fuel oil heaters
or leaking valves.
Figure 124 Fuel in the lube oil
Metal particles may indicate wear due to high vibration levels.
9. Verify all vital and non-vital alarm actions at Mk6 Control Panel function correctly.
Using the Test Menu, see section 3.5, check the correct operation of the Shutdown / Slowdown
Relays, Common Alarm Relay and Fault Relay.
CLEAR MAXIMUM AVERAGES & PEAK DEVIATION AVERAGE LEVELS AFTER TEST PROCEDURES.