ARMREST WALKAROUND
THROTTLE PANEL
14
15
16
17
18
Power Drive
REF NAME FUNCTION
14
Constant
RPM (CRPM)
Set point 1
Enables engine RPM set point 1.Press and hold
to store current engine RPM as set point 1.
15
Constant
RPM (CRPM)
Set point 2
Enable engine RPM set point 2.Press and hold
to store current engine RPM as set point 2.
16
APM
road mode
Enables Automatic Productivity Management
(APM) road/transport mode, APM eld
mode must be off.
17
APM
eld mode
Enables Automatic Productivity Management
(APM) Field mode, APM road mode must be off.
18 Not Used
This button is currently not assigned
to a function.
19
Left RPM
Control
• Manually sets engine RPM.
• Limits lower engine RPM.
20
Right RPM
Control
• Limits engine RPM used in automatic mode.
• Allows operator to set engine droop or when
ground speed reduction will occur.
When a transmission auto function is active, the display-of-gear area resizes to also show target speed and maximum
speed information for APM eld or APM road. The icons indicate which mode is active by changing color.
The normal transmission icon is grayed out when an auto function is active.
The auto transmission icon is blue when APM eld or APM road are active.
The APM eld icon is blue when APM eld is active and grayed out when APM road is active.
The APM road icon is blue when APM road is active and grayed out when APM eld is active.
Automatic Productivity Management (APM) Display
APM Field Sensitivity
Field sensitivity determines how frequently the transmission responds to load changes
during eld work. A high setting increases shift frequency. A lower setting decreases shift
frequency. If the transmission is shifting too frequently, decrease the sensitivity setting.
The changes are made by adjusting the slider to change the setting.
APM Road Sensitivity
Road sensitivity determines how frequently the transmission responds to load changes
while roading. A high setting increases shift frequency. A lower setting decreases shift
frequency. If the load is mostly constant and the transmission is not always choosing the
most efcient gear, increase the sensitivity setting. The changes are made by adjusting
the slider to change the setting.