DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
11. Refer to Hydraulic pump - Flow test (A.10.A.20
- F.40.A.45) If the flow indication for a circ uit was
approximately the same as the flow indication at the
same press ure in Test Number 1 of the Hydraulic
Pump Flow Te st , the circuit is good.
12. If the flow indication for a circuit was more than
3.8 L/min (on e gpm ) less than the flow indication
atthesamepressureinHydraulic pump - Flow
test (A.10.A.20 - F.40.A.45) Test Number 1, there
is leakage in that circuit.
1 04/05/2005
A.10.A / 28