DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
9. Loosen the clamp on the suction hose fi tting at the
hydraulic pump until hydraulic oil begins to flow from
around the fitting. Retighten the clamp.
BD04C141x 2
10. Cle an up any h
ydraulic oil from the equipment and
floor.
11. Disconnect
the fuel shutoff solenoid connector.
(Photo is for reference only.)
bd04c019
3
12. Turn the engine over for 30 seconds to allow
hydraul
ic oil from the reservoir to flow into the
hydraulic pump. Reconnect the fuel shutoff solenoid
connector.
13. Start an d run the engine at low idle for 2 to 5 minutes
and c heck for any leaks.
14. Stop the engine.
15. Check the hydraulic oil level in the reservoir and
add hydraulic oil as required. Reservo ir - Fillin g
(A.10.A.22 - F.60.A.10)
BD04C142 4
1 04/05/2005
A.10.A / 47