5-45
1 m Recursion
2 !3(V-WIN) awgwbwc
-bfwgfwfwJ
3 3(TYPE) 2( a
n
+1
) c2( a
n
) +bw
4 5(SET) 2(
a
1
) bwgwbwJ
5 1(SEL+S) f2(
) J
6 6(TABLE)
7 5(GPH-CON)
You can change the graph line color and line style from the recursion formula screen and
from the graph screen. To change from the recursion formula screen, see “To change graph
properties from the graph relation list screen” (page 5-15). To change from the graph screen,
see “To change graph properties from the graph screen” (page 5-16).
After drawing a graph, you can use Trace, Zoom, and Sketch.
Press A to return to the number table screen. After drawing a graph, you can toggle
between the number table screen and graph screen by pressing !6(GT).
k Graphing a Phase Plot from Two Numeric Sequences
You can draw the phase plot for numeric sequences generated by two expressions input in
the Recursion mode with one value on the horizontal axis and the other value on the vertical
axis. For
a
n
( a
n
+1
, a
n
+2
), b
n
( b
n
+1
, b
n
+2
), c
n
( c
n
+1
, c
n
+2
), the numeric sequence of the alphabetically
first expression is on the horizontal axis while the following numeric sequence is on the vertical
axis.
1. From the Main Menu, enter the Recursion mode.
2. Configure V-Window settings.
3. Enter two recursion formulas and select both of them for table generation.
4. Configure table generation settings.
Specify the start and end values for variable
n and the initial term for each recursion
formula.
5. Display the recursion formula number table.
6. Draw the phase plot.
Example To input the two sequence formulas for regression between two terms
a
n
+1
= 0.9 a
n
and b
n
+1
= b
n
+ 0.1
n
− 0.2, and specify initial terms a
1
= 1 and
b
1
= 1 for each. Generate a number table as the value of the n variable
goes from 1 to 10 and use it to draw a phase plot.
Use the following V-Window settings.
Xmin = 0, Xmax = 2, Xscale = 1
Ymin = 0, Ymax = 4, Yscale = 1

Table of Contents

Other manuals for Casio FX-CG10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio FX-CG10 and is the answer not in the manual?

Casio FX-CG10 Specifications

General IconGeneral
BrandCasio
ModelFX-CG10
CategoryCalculator
LanguageEnglish

Related product manuals