12. Allowable Wind Load
Wind speeds for which operator will still operate the gate (for V400 or V500 operators)
Value of A or B
dimension once
installed
100mm
140mm
180mm
220mm
260mm
300mm
340mm
Up to 1.5
metres
94km/h
119km/h
138km/h
156km/h
171km/h
186km/h
199km/h
Up to 2
metres
66km/h
85km/h
101km/h
114km/h
126km/h
137km/h
147km/h
Up to 2.5
metres
48km/h
65km/h
78km/h
89km/h
99km/h
108km/h
116km/h
Up to 3
metres
44km/h
57km/h
67km/h
76km/h
84km/h
91km/h
98km/h
Up to 3.5
metres
41km/h
51km/h
60km/h
67km/h
74km/h
80km/h
86km/h
Up to 4
metres
37km/h
46km/h
53km/h
60km/h
65km/h
71km/h
76km/h
For a 25% covered gate: (palisades, etc.) x 1.8 metre high
Gate lengths:
See page 24 or 2 for installation details 5
An electric lock must be fitted
Wind speeds for which operator will still operate the gate (for V400 or V500 operators)
Value of A or B
dimension once
installed
100mm
140mm
180mm
220mm
260mm
300mm
340mm
Up to 1.5
metres
47km/h
59km/h
69km/h
78km/h
86km/h
93km/h
100km/h
Up to 1.5
metres
47km/h
59km/h
69km/h
78km/h
86km/h
93km/h
100km/h
Up to 2
metres
33km/h
43km/h
50km/h
57km/h
63km/h
68km/h
74km/h
Up to 2.5
metres
24km/h
32km/h
39km/h
44km/h
49km/h
54km/h
58km/h
Up to 3
metres
22km/h
28km/h
34km/h
38km/h
42km/h
46km/h
49km/h
Up to 4
metres
19km/h
23km/h
27km/h
30km/h
33km/h
35km/h
38km/h
For a 100% covered gate: (Fully clad gates, etc.) x 1.8 metre high
Gate lengths:
See page 24 or 2 for installation details 5
An electric lock must be fitted