Unit
Yes/No
Yes/No
Yes/No
Yes/No
Minutes/seconds
Seconds
S, R, C
Level
Level
Level
Level
Collisions
B, C, P, S, L
Yes/No
M, S, M & S, SS
Millimeters
% (A)
Yes/No
Millimeters
Minutes/seconds
Minutes/seconds
Minutes/seconds
Minutes/seconds
Millimeters
Amps
Seconds
Seconds
Default
No
Yes
Yes
No
00:15
3
Standard
3
3
3
3
2
Buzzer
No
Master Only
10
3
No
10
30
30
30
30
5
11
0
0
Maximum
04:00
15
Max (6)
Max (6)
Max (6)
Max (6)
2
Yes
40
15
Yes
250
30
30
400
400
400
15
196
196
Minimum
00:00
2
1
1
1
1
1
No
1
1
No
3
10
10
20
20
5
4
0
0
Parameter Description
Autoclose Enabled
Autoclose From Fully Open
Autoclose From Partly Open
Autoclose From Partly Closed
Autoclose Time
Autoclose Override Time
Mode Of Operation
Motor M Opening Force
Motor M Closing Force
Motor S Opening Force
Motor S Closing Force
Max. No. Collisions
Collision Alarm Output
PCM Enabled
PCM Type
PCM Stop Short Distance
PCM Force
Leaf Delay Enabled
Leaf Delay
Opening Speed
Closing Speed
Ramp-up Distance
Ramp-down Distance
Crawl Distance
Torque Limit
Pre-Open Delay Time
Pre-Close Delay Time
UL325 Standard Profile
Page 67
Settings are fixed across standards
S, R, C (Modes of Operation) - Standard, Reversing, Condominium
B, C, P, S, L (Collision Alarm Output) - Buzzer, Courtesy Light, Safe Common, Solenoid, LED
M, S, SS (PCM Type) - Master, Slave, Short Stop