F7 group panel function group
F7.00
F7.01
F7.02
F7.03
F7.05
F7.06
F7.07
F7.08
0000: no password
Other: password protection
0: no lock
1: Full lock
2: reserved
3: All locked except PRG/S key (SHIFT function)
4: All lock except RUN and STOP keys
0: Jogging operation
1: free stop
2: Quick shutdown
3: Forward and reverse switching
4: UP/DN setting clear
0: All data is allowed to be rewritten
1: Except digital setting (F0.05) and this function
code, rewriting is prohibited
2: Except for this function code, all rewriting is
prohibited
Setting range: 0x0007~0xFFFF(3FFF )
Bit00: output frequency (Hz bright)
Bit01: set frequency (Hz flickering)
Bit02: bus voltage (V on)
Bit03: output voltage (V bright)
Bit04: output current (A is on)
Bit05: Running speed (rpm on)
Bit06: output power (% on)
Bit07: Output torque (% on)
Bit08: PID setting (% flashing)
Bit09: PID feedback (% bright)
Bit10: input terminal state
Bit11: output terminal state
Bit12: Torque setting value (% on)
Bit13: PLC current segment number
Bit14: set speed
Bit15: reserved
Setting range: 0x0000~0x000F
Bit00: Analog AI1 value (V is on)
Bit01: Analog AI2 value (V is on)
Bit02~Bit15: Reserved
Same as F7.05
0: Only valid for panel control
1: Valid for panel and terminal control
2: Valid for panel and communication control
3: Valid for all control modes
0000
0
0
0
0x0017
0x0000
0x0003
3
user password
Keypad lock function
MF (multi-function) button
function selection
Parameter protection settings
Parameter selection for operating
status display 1
Parameter selection for operating
status display 2
Parameter selection for stop state
display
STOP key stop function selection
F7.04
F7.09
F7.10
F7.11
F7.12
F7.13
F7.14
–
–
–
–
–
–
–
–
–
–
–
–
–
–
reserve
reserve
reserve
reserve
reserve
reserve
reserve
function
code
name
Parameter Description
Defaults
Change
096
NVF2G-S Series Inverter User's Guide