   X terminal function selection details are as follows:
8. 11 terminal function setting
8.11.1 Digital input terminal function (X)
   NVF2G-S series inverters are equipped with 6 multifunctional digital input terminals as standard, and each
input terminal can set the following input terminal functions .
function
code
name
default
value
F5.01
X1 terminal function selection
1
F5.02
X2 terminal function selection
4
F5.03
X3 terminal function selection
9
F5.04
X4 terminal function selection
1 2
F5.05
X5 terminal function selection
0
F5.06
X6 terminal function selection
0
F5.07
Valid state setting of input
terminal
0x0000
F5.08
Input terminal filter time
0.010s
F5.11
X1 terminal delay time
0.000s
F5.12
X2 terminal delay time
0.000s
F5.13
X3 terminal delay time
0.000s
F5.14
X4 terminal delay time
0.000s
F5.15
X5 terminal delay time
0.000s
F5.16
X6 terminal delay time
0.000s
set value
Function
0
no function
Unused terminals can be set as "no function" to prevent misoperation
1
Forward running F WD
Control the forward and reverse rotation of the inverter through external
terminals
2
Reverse running R EV
3
forward jogging
Through the operation control in the control terminal mode, the jogging operation
frequency and acceleration and deceleration time are defined in F 8.00~F8.02
4
reverse jogging
5
Three-wire operation
control
of controlling the terminal down, refer to the function introduction in " 8.1
Running command setting "
6
fault reset
which is the same as the fault reset function of the STOP key on the button,
and use this function to realize remote fault reset
7
External fault input
The fault signal of the external equipment can be input through this terminal,
which is convenient for the inverter to monitor the fault of the external
equipment. After the inverter receives the external equipment failure signal, it
will display "E.EF " , that is, the external equipment failure alarm
9
run pause
The inverter decelerates to stop, and when the terminal is valid, all operating
parameters are memorized (such as PLC parameters , P ID parameters); after
the terminal is invalid, the inverter resumes the previously memorized
operating state
10
External terminal
shutdown
This command is valid for all running command channels, and the function
terminal is valid to rule that the inverter stops according to the method set
by F 1.05 .
12
free parking
Use the control terminal to realize free running stop, which is the same as the
function defined in F 1.05
13
Terminal U P
When the frequency source is set to digital setting, when the frequency is
modified, it is used as an increment and decrement instruction, and the
modification rate is determined by the F 0.12 U P/DN adjustment rate
1 4
Terminal D OWN
NVF2G-S Series Inverter User's Guide
Predetermined area
illustrate