to correct the frequency, and the frequency is corrected after the inverter stops. The value is cleared to
zero.
   The tens place of F0.13 is 0 (the stop frequency is maintained), set the digital frequency of F0.05 with the
panel, and then correct the frequency through the up and down keys of the keyboard or terminals UP
and DOWN, and the frequency correction value after the inverter stops is reserved.
function
code
name
default
value
Predetermined area
Parameter Description
F0.05
digital setting
50.00Hz
F0.09F0.08
-
F0.07
output frequency
50.00Hz
F0.08~600.00Hz
-
F0.08
frequency cap
50.00Hz
F0.09F0.07
-
F0.09
Operating frequency
lower limit
0.00Hz 0.00HzF0.08
-
F0.13
UP/ DN adjustment
control
0x0000
0x0000 ~ 0x1111
Ones place: After the panel UP/DN modifies
the frequency
0: The frequency is not stored when power off
1: frequency power-down storage
Tens digit: After the panel UP/DN modifies
the frequency
0: Keep the stop frequency
1: Shutdown frequency restores to initial value
Hundreds place: After the terminal UP/DN
modifies the frequency
0: The frequency is not stored when power off
1: frequency power-down storage
Thousands digit: after terminal UP/DN
modifies the frequency
0: Keep the stop frequency
1: Shutdown frequency restores to initial value
8.2.3 Analog quantity setting main frequency (AI1 , AI2 setting )
   Set the main frequency through the analog input AI1, AI2, each AI terminal can set the corresponding AI
curve, the specific setting steps are as follows:
   AI curve setting method:
   There are 2 types of AI curves, among which, curve 1 corresponds to AI1, and curve 2 corresponds to AI2,
both of which are 2-point curves, and the relevant parameters are F5.27F5.34.
setup steps
Related parameters
illustrate
(Step 1) AI terminal as a frequency source:
Select the AI input terminal of the frequency
command according to the terminal
characteristics
F0.02
Main frequency selection:
F 0.02=1: AI1 terminal input to set the main
frequency
F 0.02=2: AI2 terminal input to set the main
frequency
(Step 2) AI curve setting method:
set the corresponding relationship between the
input of AI voltage/current and the set value
F5.27~F5.30
Curve 1 setting
F5.31 ~F5.34
Curve 2 setting
(Step 3) Set filter time
F5.23 ~F5.24
A I1 , A I2 filter time
function
code
name
default
value
Predetermined area
Parameter Description
F5.27
Minimum setting of AI1 curve
0.00V
0.00V~F5.29
100.0 % is the percentage
relative to the maximum
frequency F 0.07
F5.28
Corresponding setting of AI1
curve minimum reference
0.0%
( -100.0 ~ +100.0 )%
F5.29
AI1 curve maximum setting
10.00V
F5.27 ~ +11.00V
F5.30
Corresponding setting of AI1
curve maximum given
100.00%
( -100.0 ~ +100.0 )%
F5.31
Minimum setting of AI2 curve
0.00V
0.00V~F5. 33
038
NVF2G-S Series Inverter User's Guide