LCR Meter 11021 / 11021-L User’s Manual
5-6
5.3.3 Common Commands
(1) *CLS
It clears the register.
(2) *ESE <enable value>
It enables the bit of standard event enable register. The specified bit will reflect on the
status byte.
(3) *ESE?
It queries the standard event enable register. 11021/11021-L will return a decimal value
to indicate the binary set in the enable register for bit.
(4) *ESR?
It queries the standard event register. 11021/11021-L will return a decimal value to
indicate the binary of standard event register.
(5) *IDN?
It queries the identification string of 4 columns (separated by comma.)
(6) *OPC
It informs the 11021/11021-L to set the execution completed bit (bit 0) for the standard
event register when all operations are done.
(7) *RST
It sets the 11021/11021-L to return to the factory default without changing the lock
status.
(8) *SRE
It enables the bit in the status byte enable register.
(9) *SRE?
It queries the contents of status byte enable register. 11021/11021-L will return a
decimal value to indicate the binary of standard event register.
(10) *STB?
It queries the contents of status byte register.
(11) *TRG
It triggers the 11021/11021-L in bus/manual trigger mode. When the test is done, the
data will send to register automatically.
(12) *TST?
It runs self-test and returns the test result summary of errors. It returns ϕ if there is no
error.
OPEN/SHORT DATA 1
EEPROM CHECK 2
GPIB & HANDLER 4
CALIBRATION DATA 8
5.3.4 Command Description
ABORt Command
(1) Command: ABORt
Parameter: None
Return: None
Function: The command has no function.