Programmable AC Source 61601/61602/61603/61604 User’s Manual
3-4
It is the DC composition measurement readings of Voltage in Volts.
It is the DC composition measurement readings of Current in Amperes.
It is the peak current measurement in Amperes.
It is I surge, and only measured from the occurrence of output transition as defined
in 3.5.8.
It is Apparent Power in Watts, and its calculation formula = Vrms × Irms.
Its calculation formula =
3.4 CHOICE PAGE (Functional List Choice)
If displays on MAIN PAGE or on functional list, press PAGE/EXIT to change to CHOICE PAGE
as below:
Users can press 1 - 4 to choose operational list item, then press ENTER to confirm it.
The display will switch to MAIN PAGE when press PAGE/EXIT on CHOICE PAGE.
3.5 SETUP Functional List
On CHOICE PAGE (see 3.4), press 1 then ENTER, choose the SETUP functional list.
Press SHIFT , then to change to next page.
PAGE CHOICE = 1_
1. SETUP 2.CONF 3.OUTPUT 4. MANUAL CALI
PAGE CHOICE = 1_
1. SETUP 2.CONF 3.OUTPUT 4. MANUAL CALI
Vdc LMT (+) = 424.2 V Vdc LMT (-) = 0.0V
I LIMIT (A) = 0.0 DELAY (S) = 0.0