Query Syntax : [SOURce :] VOLTage : RANGe?
Parameters : LOW | HIGH | AUTO
Return Parameters : LOW | HIGH | AUTO
7.6.2.4 CONFIGURE Sub-system
[SOURce :]
CONFigure
: INHibit
: EXTernal
: COUPling
[SOURce :] CONFigure : INHibit?
Description : This command sets REMOTE INHIBIT state. There are three
states for the features of remote inhibit: OFF, LIVE, and TRIG.
Query Syntax : [SOURce :] CONFigure : INHibit?
Parameters : OFF | LIVE | TRIG
Return Parameters : OFF | LIVE | TRIG
[SOURce :] CONFigure : EXTernal
Description : This command enables or disables the external controlled
analog signal input from external devices.
Query Syntax : [SOURce :] CONFigure : EXTernal?
Parameters : OFF | ON
Return Parameters : OFF | ON
[SOURce :] CONFigure : COUPling?
Description : This command sets the coupling mode to present AC source
output from external V reference: AC_AMPLIFIER and
DC_LEVEL_CTL.
Query Syntax : [SOURce :] CONFigure : COUPling?
Parameters : AC | DC
Return Parameters : AC | DC
7.6.2.5 PHASE Sub-system
[SOURce :]
PHASe
: ON
: OFF
[SOURce :] PHASe : ON
Description : This command sets the transition angle of the waveform when it
out. Default DEGREE ON is 0 degree.
Query Syntax : [SOURce :] PHASe : ON?
Parameters : <NR2>, valid range: 0.0 ~ 359.9
Return Parameters : <NR2>
[SOURce :] PHASe : OFF
Description : This command sets the transition angle of the waveform when it
quit.