Programmable AC Source 61705 User’s Manual
8-18
TRACe : RMS
Description : This command sets the rms value of user’s waveform.
Users need to calculate the root mean square value of 1024 data
points.
Syntax : TRACe : RMS <waveform_name>, <rms>
Parameters : <waveform_name>:US<n>, n=1~6, <rms>:<NR1>, valid range:
0 ~ 32767.
Example : TRACe : RMS US1,27000
8.6.2.9 LIST Sub-system
[SOURce :]
LIST
: COUPle
: POINts?
: COUNt
: DWELl
: SHAPe
: BASE
: VOLTage
: AC
: STARt
: END
: DC
: STARt
: END
: FREQuency
: STARt
: END
: DEGRee
OUTPut
: MODE
TRIG
TRIG : STATE?
[SOURce:]LIST : COUPle
Description : This command sets the mode of list function.
Query Syntax : [SOURce:] LIST : COUPle?
Parameters : ALL | NONE
Return Parameters : ALL | NONE
[SOURce:] LIST : POINts?
Description : This command returns the number of sequences of the list
mode.
Query Syntax : [SOURce:] LIST : POINts?
Parameters : None
Return Parameters : <NR1>, valid range: 0 ~ 100
[SOURce :] LIST : COUNt