EasyManua.ls Logo

Chroma 61705 - Page 92

Chroma 61705
125 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable AC Source 61705 Users Manual
8-18
TRACe : RMS
Description : This command sets the rms value of user’s waveform.
Users need to calculate the root mean square value of 1024 data
points.
Syntax : TRACe : RMS <waveform_name>, <rms>
Parameters : <waveform_name>:US<n>, n=1~6, <rms>:<NR1>, valid range:
0 ~ 32767.
Example : TRACe : RMS US1,27000
8.6.2.9 LIST Sub-system
[SOURce :]
LIST
: COUPle
: POINts?
: COUNt
: DWELl
: SHAPe
: BASE
: VOLTage
: AC
: STARt
: END
: DC
: STARt
: END
: FREQuency
: STARt
: END
: DEGRee
OUTPut
: MODE
TRIG
TRIG : STATE?
[SOURce:]LIST : COUPle
Description : This command sets the mode of list function.
Query Syntax : [SOURce:] LIST : COUPle?
Parameters : ALL | NONE
Return Parameters : ALL | NONE
[SOURce:] LIST : POINts?
Description : This command returns the number of sequences of the list
mode.
Query Syntax : [SOURce:] LIST : POINts?
Parameters : None
Return Parameters : <NR1>, valid range: 0 ~ 100
[SOURce :] LIST : COUNt

Table of Contents