Remote Operation
8-19
Description : This command sets the number of times that the list is executed
before it is completed.
Query Syntax : [SOURce :] LIST : COUNt?
Parameters : <NR1>, valid range: 0 ~ 65535
Return Parameters : <NR1>
[SOURce :] LIST : DWELl
Description : This command sets the sequence of dwell time list points.
Query Syntax : [SOURce:] LIST : DWELl?
Parameters : <NR2>, …, <NR2> valid range: 0 ~ 99999999.9 (unit: ms)
Return Parameters : <NR2>, …, <NR2>
[SOURce :] LIST : SHAPe
Description : This command sets the sequence of waveform buffer list
points .
Query Syntax : [SOURce:] LIST : SHAPe?
Parameters : A|B, …, A|B
Return Parameters : A|B, …, A|B
[SOURce :] LIST : BASE
Description : This command sets time base of list.
Query Syntax : [SOURce:] LIST : BASE?
Parameters : TIME | CYCLE
Return Parameters : TIME | CYCLE
[SOURce :] LIST : VOLTage : AC : STARt
Description : This command sets the sequence of AC start voltage list points.
Query Syntax : [SOURce:] LIST : VOLTage : AC : STARt?
Parameters : <NR2>, …, <NR2> valid range: 0.0 ~ 150.0 (in low range),0.0 ~
300.0 (in high range)
Return Parameters : <NR2>, …, <NR2>
[SOURce :] LIST : VOLTage : AC : END
Description : This command sets the sequence of AC end voltage list points.
Query Syntax : [SOURce:] LIST : VOLTage : AC : END?
Parameters : <NR2>, …, <NR2> valid range: 0.0 ~ 150.0 (in low range),0.0 ~
300.0 (in high range)
Return Parameters : <NR2>, …, <NR2>
[SOURce :] LIST : VOLTage : DC : STARt
Description : This command sets the sequence of DC start voltage list
points.
Query Syntax : [SOURce:] LIST : VOLTage : DC : STARt?
Parameters : <NR2>, …, <NR2> valid range: -212.1 ~ 212.1 (in low range),
-424.2 ~ 424.2 (in high range)
Return Parameters : <NR2>, …, <NR2>
[SOURce :] LIST : VOLTage : DC : END
Description : This command sets the sequence of DC end voltage list
points.
Query Syntax : [SOURce:] LIST : VOLTage : DC : END?
Parameters : <NR2>, …, <NR2> valid range: -212.1 ~ 212.1 (in low range),
-424.2 ~ 424.2 (in high range)
Return Parameters : <NR2>, …, <NR2>