Language Dictionary
7-23
Query Example PROG:ONT?
Return Example 10
PROGram:OFFTime
Description Set the load off time of program file
Syntax PROGram:OFFTime <NRf>[suffix]
Parameter 0~30 Sec
Example PROG:OFFT 20
PROG:OFFT 200ms
Query Syntax PROGram:OFFTime?
Return Parameter <NR2> [Unit=Sec]
Query Example PROG:OFFT?
Return Example 0.2
PROGram:PF:DELay
Description Set the pass/fail measurement delay time of program file.
Syntax PROGram:PF:DELay <NRf>[suffix]
Parameter 0~60 Sec
Example PROG:PF:DELay 20
PROG:PF:DELay 200ms
Query Syntax PROGram:PF:DELay?
Return Parameter <NR2> [Unit=Sec]
Query Example PROG:PF:DEL?
Return Example 0.2
PROGram:PF:TIME
Description Set the pass/fail measurement time of program file
Syntax PROGram:PF:TIME <NRf>[suffix]
Parameter 0~60 Sec
Example PROG:PF:TIME 20
PROG:PF:TIME 200ms
Query Syntax PROGram:PF:TIME?
Return Parameter <NR2> [Unit=Sec]
Query Example PROG:PF:TIME?
Return Example 0.2
PROGram:RUN
Description Execute the program run according to the set program file.
Syntax PROGram:RUN <NR1 | CHAR>
Parameter 0 | OFF, 1 | ON
Example PROG:RUN ON
PROG:RUN 0
Query Syntax PROGram:RUN?
Return Parameter 0 | 1
Query Example PROG:RUN?
Return Example 0 (OFF)
PROGram:SAVE
Description Save the program setting.
Syntax PROGram:SAVE
Parameter NONE
Example PROG:SAVE
PROGram:SEQuence
Description Set the program file sequence.

Table of Contents

Other manuals for Chroma 63200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63200 Series and is the answer not in the manual?

Chroma 63200 Series Specifications

General IconGeneral
BrandChroma
Model63200 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals