High Power DC Electronic Load 63200 Series Operation & Programming Manual
7-22
7.2.9 PROGram Sub-system
PROGram
:CHAin
:FILE
:KEY
:ONTime
:OFFTime
:PF
:DELay
:TIME
:RUN
:SAVE
:SEQuence
:MODE
:SHORt
:DELay
:TIME
PROGram:CHAin
Description Set the type of program file in serial execution.
Syntax PROGram:CHAin <NRf>
Parameter 0 to 10 (0 does not chain.)
Example PROG:CHA 7
Query Syntax PROGram:CHAin?
Return Parameter <NR1>
Query Example PROG:CHA?
Return Example 7
PROGram:FILE
Description Set the program number.
Syntax PROGram:FILE <NRf>
Parameter 1 to 10
Example PROG:FILE 10
Query Syntax PROGram:FILE? Return the active program number.
Return Parameter <NR1>
Query Example PROG:FILE?
Return Example 10
PROGram:KEY
Description Set the next step of program manual sequence
Syntax PROGram:KEY <CHAR>
Parameter K0~K9 | KU KD
Example PROG:KEY KD
PROGram:ONTime
Description Set the load on time of program file.
Syntax PROGram:ONTime <NRf>[suffix]
Parameter 0~30 Sec
Example PROG:ONT 10
PROG:ONT 100ms
Query Syntax PROGram:ONTime?
Return Parameter <NR2> [Unit=Sec]

Table of Contents

Other manuals for Chroma 63200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63200 Series and is the answer not in the manual?

Chroma 63200 Series Specifications

General IconGeneral
BrandChroma
Model63200 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals