Installation
2-9
2.4.5 Parallel Setting
Power on the Electronic Load and it will start self-test to check the system as well as the
RS-232 and GPIB Interface. The LCD shows:
Next, it will show the CC mode settings.
Press SYS to set the RS485 address of Slave so that it can be followed when setting the
attribute of Master.
First, it will prompt the default GPIB address.
Next, press ↓→ to RS485 ADDRESS setting mode. The setting of RS485 ADDRESS maps
to the slave number, for instance if RS485 ADDRESS = 2, the salve number is SLAVE 2.
Press 1, ENTER to set the RS485 ADDRESS to 1.
When the setting is done, it will show several RS-232 parameter setting modes (Note 2).
Press ↓→ to skip these modes until PARALLEL setting mode appears. (Note1):
Set the Electronic Load to slave and press 2, ENTER:
When the slave setting is done, it will prompt SYS setting automatically as shown below:
FRONT PANEL TESTING
[ RS232 ] PASS
FRONT PANEL TESTING
CHECKSUM PASS
GPIB ADDRESS X
CHROMA ATE INC.
MODEL 632XX
GPIB ADDRESS
X
RS485 ADDRESS
1
CCHA: 0.0000A
CCHB: 0.0000A
PARALLEL = NONE
PRESS 0 3 TO SELECT
PARALLEL = SLAVE
PRESS 0 3 TO SELECT