2-14 Installation
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright
©
2012-2015 Ciena
®
Corporation July 2015
Ethernet Cables
The following ports on the 5150 use Ethernet cables and have standard RJ-45
jacks:
MGMT 10/100/1000 Port
Console Port
Copper SFPs — copper SFPs are supported on any of the SFP ports
Note: Copper SFP ports must be cabled with shielded Cat 5e or better.
The shielded cable must be grounded at both ends.
To install a Cat 5e cable, insert the connector into the port on the device until
you hear a clicking sound. Insert the tail end of the cable into the port on the
terminating device.
Initial Configuration
Two different methods can be used to assign an IP address to the device:
using a DHCP server to automatically assign an IP address
(recommended)
configuring the IP address manually.
Both methods are accomplished through the CLI and are not described in this
document. See “Turning Up the System” on page 3-1 for more information.
Note: If the device has not been assigned an IP address other than the
default IP address (either manually or through a DHCP server)
communication can only take place through the local management port.
Initial IP address configuration must therefore be done through the local
management port.
CAUTION: Use caution when setting an IP address or subnet mask, the new value
takes effect immediately. If information is set that is inconsistent with network
settings, communication with the device may no longer be possible. If all other
troubleshooting methods have been exhausted, recovery may be possible using the
Reset button
.