48
LE-3xx/LE-4xx Hardware Installation & User Guide
POWER CONSUMPTION
Power Consumption
The following tables detail the power consumption for the various SCS/SDS device
models. The following definitions should be taken into account when reading
these tables:
•
Minimum Load
: A device that is functional but has no optics,
loopbacks, or traffic running.
•
Maximum Load
: A device that is functional and is fully populated
with optics, fiber runs, and/or Cat5 cables looped from port to port.
No traffic or loopback test running.
•
BTU/hr Calculation
: Watts * 3.4129
Standard MIB Support SNMP MIB II (RFC 1213)
Bridge MIB (RFC 1493)
MIB II interfaces (RFC 1573)
RMON MIB (RFC 1757)
RMON II (RFC 2021)
Ethernet-like Interface MIB (RFC 1643)
Physical
Chassis Dimensions
LE-310
LE-311/311v
LE-327/LE-427
Weight
Rack Unit Height
LE-310/311/311v/327
44.2 mm H x 444.5 mm W x 292.1 mm D
(1.74 in H x 17.5 in W x 11.5 in)
44.2 mm H x 444.5 mm W x 393.7 mm D
(1.74 in H x 17.5 in W x 15.5 in)
44.2 mm H x 444.5 mm W x 368.3 mm D
(1.74 in H x 17.5 in W x 14.5 in)
LE-310: 9 lbs (4.08 kg)
All others: 14 lbs. (6.3580 kg)
1 RU
Environmental
Ambient Operating Temperature
Operating Humidity
0 – 40 C (32 – 104 degrees F)
0 – 90% RH, non-condensing
Table A-1: Specifications