EasyManua.ls Logo

Ciena LE-427 - SNMP Traps

Ciena LE-427
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
LE-3xx/LE-4xx Hardware Installation & User Guide
SNMP TRAPS
SNMP Traps
The following table lists standard SNMP traps on the device.
Tab le A -3: SNMP Tra ps
Trap MIB Type Description
Cold Start MIB II Trap generated after device successfully
reboot.
Authentication Failure MIB II Trap generated when values are attempted to
be set using incorrect community string.
Link Up/Down MIB II Link up/down trap.
RMON Events
(risingAlarm, fallingAlarm)
WWP RMON statistics.
topologyChange WWP Network topology change.
wwpLinkUp/
wwp
LinkDown WWP
WWP
link up/link down Status.
wwpBcastThresholdExceed WWP Number of broadcast packets received
exceeds configured packet limit.
wwpPvstBpduReceived WWP Sent when Per VLAN Spanning Tree (PVST)
BPDU is received.
wwpEnvPowerSupplyStatusNotification WWP Device power supply state change.
wwpEnvFanModuleNotification WWP Device fan state change.
wwpEnvTempNotification WWP Device temperature state change.
wwpEnvPowerSwitchNotification WWP Power supply switched to/from AC/DC to
battery or to/from battery to AC/DC.
wwpFTransferCompletion WWP File transfer status.
wwpFTransferCmdParseError WWP Command file failure.
wwpIpInterfaceAddrChgNotification WWP Whenever interface IP is changed.
wwpSystemLoadBackupAppNotification WWP Whenever systems load backup image.
wwpXcvrLinkStateChangeNotification WWP Transceiver state change.
wwpXcvrErrorTypeNotification WWP Transceiver error type.