C-2
Cisco CGS 2520 Hardware Installation Guide
OL-31444-01
Appendix C      Configuring the Switch with the CLI Setup Program
Accessing the CLI Through the Console Port
Figure C-1 Connecting the Console Cable 
Step 3
Configure the baud rate and character format of the PC or terminal to match the console port 
characteristics:
 • 9600 baud
 • 8 data bits
 • 1 stop bit
 • No parity
 • None (flow control)
Step 4 Connect power to the switch as described in the “Power Supply Module Installation” section on 
page 3-2.
Step 5 The PC or terminal displays the bootloader sequence. Press Enter to display the setup prompt. Follow 
the steps in the “Completing the Setup Program” section on page C-7.
1 RJ-45 console port 2 Console cable (RJ-45-to-DB-9 adapter cable)
207536
2
1
1