DescriptionItem
SIM 1 (away from device)3
Step 5 Push in each SIM until it clicks into place. When the SIMs are installed, re-attach the access plate previously removed
with a screwdriver. Torque to 2.8 to 3.8 inch-lbs (0.9-1.1 newton meter).
Note: Ensure the cover is properly aligned with the screw hole.
Step 6 If your Pluggable Module is the type that has a USB port, make sure that the USB cover is properly installed. Place the
USB cover (1) with the plug indentation against the USB port (2). The half circle of the USB cover fits behind the latch
lock screw. See Figure 23: USB Port Cover Installation, on page 40 for details.
Figure 23: USB Port Cover Installation
Step 7 Tighten the latch lock screw to a torque of 2.8 to 3.8 inch-lbs (0.3 to 0.4 newton meter). Refer to Figure 24: USB Cover
Finished Installation, on page 41 for a finished USB cover installation.
IR1101 Industrial Integrated Services Router Hardware Installation Guide
40
Installing the Router
Pluggable Module