EasyManuals Logo

Cisco MDS 9700 Series User Manual

Cisco MDS 9700 Series
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
6 NA 1.0
Xbar MAC-Address(es) Serial-Num
--- -------------------------------------- ----------
1 NA JAE222305VS
2 NA JAE2217096X
3 NA JAE222305V5
4 NA JAE2217096L
5 NA JAE2217096J
6 NA JAE222305V8
Step 12 (Optional) If the standby Supervisor-1 Module is not in the po wered-dn state, then put the standby Supervisor-1 Module
to out of service, using the out-of-service module slot command .
where a slot indicates the chassis slot number in which the standby supervisor module resides.
switch(config)# out-of-service module 6
Step 13 Physically replace the standby Supervisor-1 Module (slot 6) with the second Supervisor-4 Module. To replace the
supervisor module, follow the steps explained in the “Installing a Supervisor Module” section and the “Removing a
Supervisor Module” section.
The following message is displayed:
2019 Jun 25 15:21:13 switch %PLATFORM-2-SINGLE_EJECTOR_STAT_CHANGED: Ejector's status in slot 6 has
changed, Ejector is OPEN
2019 Jun 25 15:21:15 switch %PLATFORM-2-MOD_REMOVE: Module 6 removed (Serial number JAE17440HVB)
After inserting the new standby Supervisor-4 Module, the following message is displayed:
2019 Jun 25 15:21:27 switch %PLATFORM-2-MODULE_EJECTOR_POLICY_ENABLED: All Ejectors closed for
module 6. Ejector based shutdown enabled
2019 Jun 25 15:21:27 switch %PLATFORM-2-MOD_DETECT: Module 6 detected (Serial number :unavailable)
Module-Type Supervisor Module-4 Model :unavailable
Step 14 Wait for approximately 20 minutes for the new Supervisor-4 Module to come up in the HA-standby state. Once the
standby supervisor module is in the HA-standby state, the supervisor Status LED will be green.
If you see the following failure message, ignore the message, the active Supervisor-4 Module will bring up the standby
Supervisor-4 Module to the HA-standby supervisor state in some time.
2019 Jun 25 15:36:45 switch %SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up.
The following message is displayed on the active Supervisor-4 Module:
2019 Jun 25 15:36:45 switch %USBHSD-STANDBY-2-MOUNT: logflash: online
2019 Jun 25 15:36:49 switch %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor
supervisor, starting...
2019 Jun 25 15:38:30 switch %PLATFORM-1-PFM_ALERT: Disabling ejector based shutdown on sup in slot
6
2019 Jun 25 15:39:38 switch %MODULE-5-STANDBY_SUP_OK: Supervisor 6 is standby
2019 Jun 25 15:39:39 switch %PLATFORM-1-PFM_ALERT: Enabling ejector based shutdown on sup in slot
5
Step 15 Reinstall the license files on the new Supervisor-4 Modules.
switch(config)# copy usb1:licenses_archive_file_name.tar bootflash:switch_license.tar
Copy progress 100% 10KB
Copy complete, now saving to disk (please wait)...
switch(config)# copy bootflash:switch_license.tar bootflash:switch_license.lic
Copy progress 100% 10KB
Cisco MDS 9700 Series Switches Hardware Installation Guide
129
Installing, Removing, and Verifying Field Replaceable Units
Performing a Nondisruptive Migration

Table of Contents

Other manuals for Cisco MDS 9700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9700 Series and is the answer not in the manual?

Cisco MDS 9700 Series Specifications

General IconGeneral
BrandCisco
ModelMDS 9700 Series
CategorySwitch
LanguageEnglish

Related product manuals