EasyManuals Logo

Cisco MDS 9700 Series User Manual

Cisco MDS 9700 Series
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #156 background imageLoading...
Page #156 background image
NAME: "Slot 14", DESCR: "Fabric card module"
PID: DS-X9710-FAB1 , VID: V00, SN: JAE2217096L
NAME: "Slot 15", DESCR: "Fabric card module"
PID: DS-X9710-FAB1 , VID: V00, SN: JAE2217096J
NAME: "Slot 16", DESCR: "Fabric card module"
PID: DS-X9710-FAB1 , VID: V00, SN: JAE222305V8
NAME: "Slot 35", DESCR: "MDS 9710 (10 Slot) Chassis Power Supply"
PID: DS-CAC97-3KW , VID: V01, SN: DTM164602XH
NAME: "Slot 37", DESCR: "MDS 9710 (10 Slot) Chassis Power Supply"
PID: DS-CAC97-3KW , VID: V01, SN: DTM1649022W
NAME: "Slot 38", DESCR: "MDS 9710 (10 Slot) Chassis Power Supply"
PID: DS-CAC97-3KW , VID: V01, SN: DTM16490239
NAME: "Slot 39", DESCR: "MDS 9710 (10 Slot) Chassis Power Supply"
PID: DS-CAC97-3KW , VID: V01, SN: DTM164602ZP
NAME: "Slot 41", DESCR: "MDS 9710 (10 Slot) Chassis Fan Module"
PID: DS-C9710-FAN , VID: V00, SN: JAF1647ADCE
NAME: "Slot 42", DESCR: "MDS 9710 (10 Slot) Chassis Fan Module"
PID: DS-C9710-FAN , VID: V00, SN: JAF1647ADCN
NAME: "Slot 43", DESCR: "MDS 9710 (10 Slot) Chassis Fan Module"
PID: DS-C9710-FAN , VID: V00, SN: JAF1647ACHH
Sample output for the show interface brief command on the Supervisor-4 Module:
switch# show interface brief
--------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port Logical
Mode Trunk Mode Speed Channel Type
Mode (Gbps)
--------------------------------------------------------------------------------
fc1/1 1 E on trunking swl TE 16 1 core
fc1/2 1 E on trunking swl TE 16 1 core
fc1/3 1 E on trunking swl TE 16 1 core
fc1/4 1 E on trunking swl TE 16 1 core
fc1/5 1 E on trunking swl TE 16 1 core
fc1/6 1 E on notConnected swl -- -- -- --
fc1/7 20 auto off up swl F 8 -- edge
fc1/8 20 F off up swl F 16 -- edge
Sample output for the show interface status command on the Supervisor-4 Module:
switch# show interface status
fc1/1 is trunking
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:01:54:7f:ee:eb:7a:00
Peer port WWN is 20:41:00:2a:6a:5b:da:80
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Admin Speed is auto max 32 Gbps
Operating Speed is 16 Gbps
Rate mode is dedicated
Cisco MDS 9700 Series Switches Hardware Installation Guide
142
Installing, Removing, and Verifying Field Replaceable Units
Verification

Table of Contents

Other manuals for Cisco MDS 9700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9700 Series and is the answer not in the manual?

Cisco MDS 9700 Series Specifications

General IconGeneral
BrandCisco
ModelMDS 9700 Series
CategorySwitch
LanguageEnglish

Related product manuals