Power Usage Summary:
--------------------
Power Supply redundancy mode (configured) Non-Redundant(combined)
Power Supply redundancy mode (operational) Non-Redundant(combined)
Total Power Capacity (based on configured mode) 6000 W
Total Power of all Inputs (cumulative) 6000 W
Total Power Output (actual draw) 2245 W
Total Power Allocated (budget) 5192 W
Total Power Available for additional modules 806 W
switch#
Displaying the Current State of a Module
You can display information about modules that are installed in the switch chassis by using the show module
command. This information includes module type, bootup status, MAC addresses, serial numbers, software
versions, and hardware versions. You can use this command in the following ways to display information
about all the installed modules or a specific module:
For information on all modules, use the show module command.
For information on a specific supervisor, system controller, line card, or fabric module, use the show
module slot_number command to specify a slot number.
To determine the slots to specify, use the show inventory command.
Note
This command reports on only software-controlled modules, such as supervisors, system controllers,
line cards, fabric modules, fan trays, and power supplies. It doesn’t report on modules that are not
software controlled, such as blank modules installed in empty slots to control airflow.
Note
This table provides descriptions of the module status that is displayed with the show module commands.
DescriptionLine Card State
The hardware has electrical power. When the hardware is powered up, the software
begins booting.
powered up
The module has established connection with the supervisor and the module is
performing bootup diagnostics.
testing
The diagnostics have completed successfully and the configuration is being downloaded.initializing
The switch detects a module failure upon initialization and automatically attempts to
power-cycle the module three times. After the third attempt, the module powers down.
failure
The switch is ready to be configured.ok
The switch detects insufficient power for a line card to power up.power-denied
Cisco Nexus 9508 NX-OS Mode Switch Hardware Installation Guide