EasyManua.ls Logo

Cisco ONS 15454 M6 - Page 113

Cisco ONS 15454 M6
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 2 Verify that the DC power module is installed in Slot A or Slot B (or both slots) of the ONS 15454 M6.
Step 3 Unscrew the screws to a torque value of 4 in-lb (0.45 N-m) to remove the protective covers from the DSUB
power connector of the DC power modules (see the following figure).
Figure 87: Connecting Office PowerDC Power Modules (ETSI Only)
Step 4 Attach the DC ETSI power cable to the cable connector in the DC power module (see the following figure).
Step 5 Tighten the screws to a torque value of 4 in-lb (0.45 N-m) to secure the cable (see the following figure).
Installing the ONS 15454 M6 Shelf
113
Installing the ONS 15454 M6 Shelf
DLP-G573 Connect Office Power (DC) to the ONS 15454 M6 Shelf (ETSI Only)

Table of Contents

Related product manuals