Step 11 Install the ONS 15454 M6 empty chassis between the horizontal plenums.
Figure 25: Installing the ONS 15454 M6 chassis below the horizontal air plenum
Step 12 Return to your originating procedure (NTP).
Air Flow Performance of ONS 15454 M6
The tables below summarizes the air flow performance of ONS 15454 M6:
Worst Controller
Card Slot (#8) Flow,
CFM
Worst Line Card
Slot (#7) Flow,
CFM
Deflector
Configuration
Case
13500 RPM
(40°C and
55°C)
9600 RPM
(27°C)
13500 RPM (40°C
and 55°C)
9600 RPM
(27°C)
2114.922.416No deflectorsSide to Side
106.911.28.2Inlet and OutletETSI Front to Rear
18.412.716.812.2Only InletETSI Front to Side
14.710.618.713.4Inlet and OutletANSI Front to
Rear
19.714.120.714.8Only InletANSI Front to Side
Bulk Chassis Flow, CFMDeflector ConfigurationCase
13500 RPM9600 RPM
Installing the ONS 15454 M6 Shelf
23
Installing the ONS 15454 M6 Shelf
Air Flow Performance of ONS 15454 M6