DLP-G296 Install Timing Wires on ONS 15454 M6 - ANSI
This task installs the timing cables on the ONS 15454 M6 ECU module for ANSI.Purpose
Wire-wrap tool and 100-ohm wire-wrap cable.Tools/Equipment
NTP-G253 Install the ECU or ECU-S Module, on page 79.Prerequisite Procedures
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Procedure
Step 1 Locate the timing connector on the ECU module (BITS-1 or BITS-2 In/Out). The following figure shows
ECU module ANSI wire-wrap pins. Table 7: ECU module Pin Assignments - ANSI, on page 133 lists the
ECU module pin assignments for ANSI.
Figure 100: ECU module ANSI Wire-wrap Pins
Table 7: ECU module Pin Assignments - ANSI
FunctionPin
Input from external driveIN 1
Output to external driveOUT 1
Input from external driveIN 2
Output to external driveOUT 2
Step 2 Connect one end of the wire-wrap clock cable to the corresponding wire-wrap connector on the ECU module,
and the other end to the external source of the timing. Change the timing input to high-impedance (lesser or
greater than 3 ohms) using a jumper on the ECU module. Remove the P1 jumper of the BITS-1 to change the
top timing input, and the P2 Jumper of the BITS-2 to change the bottom timing input.
Installing the ONS 15454 M6 Shelf
133
Installing the ONS 15454 M6 Shelf
DLP-G296 Install Timing Wires on ONS 15454 M6 - ANSI