Plug the other end into the MSM port of the node controller ONS 15454 M6 shelf that
corresponds to the TNC/TNCE/TSC/TSCE card in Slot 1.
b) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the MSM port of the subtending ONS 15454 M6 shelf that corresponds
to the TNC/TNCE/TSC/TSCE card in Slot 8.
Plug the other end into the MSM port of the node controller ONS 15454 M6 shelf that
corresponds to the TNC/TNCE/TSC/TSCE card in Slot 1.
c) Repeat Step 1a and Step 1b to connect the remaining MSM ports on the node controller ONS 15454 M6
shelf to the MSM ports on the subtending ONS 15454 M6 shelf.
Step 2 To connect an ONS 15454 subtending shelf to the ONS 15454 M6 node controller, complete the following:
a) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the front panel of the subtending shelf TCC2/TCC2P/TCC3 card in
Slot 7.
Plug the other end into the MSM port of the node controller ONS 15454 M6 shelf that
corresponds to the TNC/TNCE/TSC/TSCE card in Slot 1.
b) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the front panel of the subtending shelf TCC2/TCC2P/TCC3 card in
Slot 11.
Plug the other end into the MSM port of the node controller ONS 15454 M6 shelf that
corresponds to the TNC/TNCE/TSC/TSCE card in Slot 8.
c) Repeat Step 2a and 2b for each subtending shelf in the multishelf configuration using the remaining MSM
ports on the node controller ONS 15454 M6 shelf.
Step 3 To connect an ONS 15454 subtending shelf to the ONS 15454 M6 subtending shelf, complete the following:
a) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the front panel of the subtending shelf TCC2/TCC2P/TCC3 card in
Slot 7.
Plug the other end into the MSM port of the subtended ONS 15454 M6 shelf that corresponds
to the TNC/TNCE/TSC/TSCE card in Slot 1.
b) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the front panel of the subtending shelf TCC2/TCC2P/TCC3 card in
Slot 11.
Plug the other end into the MSM port of the subtended ONS 15454 M6 shelf that corresponds
to the TNC/TNCE/TSC/TSCE card in Slot 8.
c) Repeat Step 3a and 3b for each subtending shelf in the multishelf configuration using the remaining MSM
ports on the subtending ONS 15454 M6 shelf.
Installing the ONS 15454 M6 Shelf
144
Installing the ONS 15454 M6 Shelf
DLP-G729 Connect the ONS 15454 M6 as the Node Controller in a Mixed Multishelf Configuration without a Catalyst Switch

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 M6 and is the answer not in the manual?

Cisco ONS 15454 M6 Specifications

General IconGeneral
Slots6
Form FactorRack-mountable
ManagementCisco Transport Controller (CTC)
Network InterfacesEthernet, SONET/SDH, OTN
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Relative Humidity5% to 95% non-condensing
Supported ServicesSONET/SDH, Ethernet, OTN

Related product manuals