1050 W AC Power Supply
This section lists the specifications for each 1050 W AC power supply (Cisco part number
UCSC-PSU1-1050W).
Table 13: 1050 W AC Specifications
SpecificationDescription
Nominal range: 100120 VAC, 200240 VAC
(Range: 90132 VAC, 180264 VAC)
AC Input Voltage
Nominal range: 50 to 60Hz
(Range: 4763 Hz)
AC Input Frequency
12.5 A at 100 VAC
6.0 A at 208 VAC
Maximum AC Input current
1250 VA at 100 VACMaximum input volt-amperes
15 A (sub-cycle duration)Maximum inrush current
12 ms at 1050 WMaximum hold-up time
800 W at 100120 VAC
1050 W at 200240 VAC
Maximum output power per PSU
12 VDCPower supply output voltage
12 VDCPower supply standby voltage
Climate Savers Platinum Efficiency (80Plus Platinum certified)Efficiency rating
RSP2Form factor
IEC320 C14Input connector
1600 W AC Power Supply
This section lists the specifications for each 1600 W AC power supply (Cisco part number
UCSC-PSU1-1600W).
Table 14: 1600 W AC Specifications
SpecificationDescription
Cisco UCS C240 M5 Server Installation and Service Guide
123
Server Specifications
Power Specifications

Table of Contents