A-2
Cisco UCS C460 Server Installation and Service Guide
OL-22326-01
Appendix A Server Specifications
Environmental Specifications
Environmental Specifications
Table A-2 lists the environmental specifications for the server.
Power Specifications
Table A-3 lists the specifications for each power supply.
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Ta b l e A-2 Environmental Specifications
Description Specification
Temperature, operating 10ºC to 35ºC (50ºF to 95ºF)
Temperature, non-operating -40ºC to 70ºC (-40ºF to 158ºF)
Humidity, non-operating 95%, non-condensing at temperatures of
25ºC (77ºF) to 30ºC (86ºF)
Altitude -30m to 1500m (-100ft to 5000ft)
Ta b l e A-3 Power Supply Specifications
Description Specification
AC input voltage 115 to 230 VAC nominal (Range: 90 to 264 VAC)
AC input frequency 50 to 60 Hz nominal (Range: 47 to 63 Hz)
Maximum AC-input current 10A
Maximum output power for each power
supply
850W (up to four power supplies can be installed)
Power supply output voltage Main power: 12 VDC
Standby power: 3.3 VDC