Starting hexadecimal dump
1
Open the top cover.
2
While pressing the FEED switch, turn
on the power of the printer “
”.
3
When you close the cover “”, a
message “Hexadecimal Dump” is
printed on paper, and then the data
received afterward is printed in
hexadecimal numbers and the
corresponding characters.
• If a character is not available
corresponding to the data received,
“ . ” is printed instead.
During hexadecimal dump, no
other functions than DLE EOT and
DLE ENQ work.
If the data received is not enough
for a full line, pressing the FEED
switch causes the line to be
printed.
<Example of hexadecimal dump>
Quitting hexadecimal dump
4
After hexadecimal printing, this
function is terminated when you
turn off the power or when a reset
signal is received from the interface.
1
2
1
4.10 Hexadecimal Dump
=== Hexadecimal Dump ===
Hexadecimal dump function allows data sent from the host computer to be printed in
hexadecimal numbers as well as in characters corresponding to the numbers.