Adjustment Procedures
5-24
750-96 (revised 2010)
Model CB Packaged Boiler Manual
reduced to a point that permits sufficient temperature to heat the oil while allowing as continuous a steam flow as
possible. Reduced pressure that is too high will result in frequent cycling of the steam solenoid valve.
It is best to adjust the regulator under typical flow conditions. To do this it is suggested that the glove valve in the
steam supply line be closed so that there is no pressure on the regulator. Turn out the adjusting screw fully to
relieve compression on the regulator spring thus closing the regulator. With steam at normal pressure, open the
globe valve and then set the secondary pressure by turning the adjusting screw or handle until the downstream
gauge shows the desired pressure.