Tro ub lesho o t ing
5
EN
M1< Torque M1, threshold not reached
M1> Torque M1 exceeded
M2< Torque M2, threshold not reached
M2> Torque M2 exceeded
MDTE> Maximum distribution torque exceeded
ME> Press-in torque too high
NECK Socket or nutrunner break
NOT End due to emergency stop
OFF1 Offset error, Transducer 1
P1M> Torque in Phase 1 too high
P2M< Torque in Phase 2 too low
P2M< Phase 2: Torque too low
P2M> Torque in Phase 2 too high
P2M> Phase 2: Torque too high
P2UU To much under- and overstep in Phase 2
P3M< Phase 3: Torque too low
P3M> Phase 3: Torque too high
P4M< Phase 4: Torque too low
P4M> Phase 4: Torque too high
PAR Wrong parameter
PS? Wrong parameter set
RAM Memory error, measuring board
SA Canceled by removal of the start signal
SeBB No ready signal for servo
SS> Max. number of cycles for stick-slip exceeded
TDS Shutoff by depth sensor
TEB< Threshold for low evaluation torque not reached
TET> High evaluation torque exceeded
TMAX Canceled by exceeding the max. time
TQ< Torque too low
TQ> Torque too high
TQSI Safety torque exceeded
TQUE Torque too high
TQUN Torque too low
TTT< Angular redundancy below min. value after time
TTT> Angular redundancy exceeded after time
WG1D Error in Angle Encoder 1
WIG< Total angle too small
WIG> Total angle too large
ZRF Gear defective
Error message Description