Troubleshooting
52 P2398PM | 2018-10 Apex Tool Group GmbH
5
EN
5 Troubleshooting
Error messages, software updates and data storage
Error messages for shut-off cause
Error message Description Measure
E1 Export script not available. Try to export the script two to three
times.
If the error message continues to
occur, perform a software update.
E2 Error during export. Connect USB stick.
Check USB stick for errors.
E3 Error while writing the archive. Check USB stick for errors.
E10 Software update script not available. Try two to three times to perform the
software update.
If the error message continues to
occur, contact the service depart-
ment at Apex Tool Group GmbH.
E50 Crash during software update.
E99 Timeout on startup expired. Connect USB stick.
E200 Several .tma files available. Make sure that there is only one
.tma file on the USB stick.
E210 No compatible update packages found. Make sure there is a .tma file on the
USB stick.
Error message Description
?S? Abort due to other errors
Abbr Abort by the controller
AN1F Transducer 1 absent
Ang< Angle too small
Ang> Angle too large
BLOC Tightened on block
COMM Host<-->TM communication error
Erg? Measuring board provides no result
EV< Not enough measured values for evaluation
FC< Clamping force too low
FC> Clamping force too great
FL> Max. time for stick-slip exceeded
FLT Servo warnings
FMK Measuring board error
FPEF Error in Snug Point Detection
FRC< Residual clamping force too low
FRC> Residual clamping force too great
FSMW Not enough rundown data
GD< Gradient too small
GD> Gradient too large
GEB? Encoder error torque/angle
IP Error output section, excessive current
IRED Current/TQ redundant
JMP Error due to the socket slipping off
KAL1 Calibration error, Transducer 1
LFF Bearing fault