Do you have a question about the CLIVET ELFOControl2 and is the answer not in the manual?
Brand | CLIVET |
---|---|
Model | ELFOControl2 |
Category | Controller |
Language | English |
Guidance for safe and correct operation of the system, including breakdown procedures.
Details on displayed information for heat pump, DHW, ELFOFresh, system areas, and general status.
Functions for controlling the system: on/off, scheduling, and 'Away' mode.
Procedures for navigating the display, saving changes, and accessing help features.
Accessing alarm information and system settings, with access restrictions noted.
Detailed steps for starting up, shutting down, and scheduling the system's operation.
Instructions on how to change the system's operating mode (heating, cooling, automatic).
Procedure for setting the system's date and time for accurate operation.
Information displayed regarding heat pump operation and component status.
How the heat pump operates automatically for both air-conditioning and hot water.
Configuration to use the heat pump solely for domestic hot water production.
Steps to switch off the heat pump functionality.
Display of system components and their water temperature status.
Configuration of operation set points for each circuit, including winter/summer and fixed/compensated.
Customizing set points for individual hydraulic circuits within the system.
Setting regular intervals for set points, distinguishing between summer and winter.
Defining fixed or compensated supply water set points based on outdoor temperature.
Setting a specific fixed temperature for the circuit.
Configuring circuits based on connected system components like mixed or non-mixed types.
Procedure to switch a circuit's set point from fixed to compensated mode.
Setting the compensation curve for water set points based on outdoor air temperature.
Detailed modification of the compensated set point curve using four points.
Direct modification of the supply set point values.
Adjusting outdoor temperature settings for compensated set points.
Modifying the compensated set point curve by adjusting 4 specific points.
Applying rapid adjustments (correction) to the climatic curve without altering set points.
Details on displayed information for domestic hot water, including temperatures.
Modes of operation for domestic hot water production (automatic, solar, auxiliary).
Configuration options for domestic hot water, including set points and solar collector activation.
Details on the preset time schedules and programming capabilities for DHW.
Example of how to program domestic hot water settings for a specific day.
Description of the operation profile for domestic hot water programming.
Details on ELFOFresh² air information and how to select a unit for operation.
Setting ELFOFresh² operation modes: automatic, ventilation only, scheduled, or excluded.
Setting ambient air and humidity set points for ELFOFresh² operation.
Setting up daily time schedules for fresh air provision, including modes like Normal, Reduced, and Off.
An example illustrating the programming of fresh air schedules for a specific day.
Description of different operation profiles for fresh air units.
Configuring system operation for climatic zones, fresh air, and DHW during 'Away' mode.
Procedure to enable or disable the 'Away from Home' functionality.
Setting zone operations via scheduling or manual control, including modes and programs.
Adjusting temperatures for individual components within a zone.
Defining Comfort/Economic modes, assigning programs, and setting area temperatures.
Selecting the season (winter/summer) and day of the week for zone programming.
Choosing available summer or winter programs for zone scheduling.
Adjusting temperatures for Comfort and Economic profiles and their differences.
Forcing zone operation modes (Comfort, Economic, Off) manually for a set duration.
Adjusting temperatures for individual components within a zone.
Illustrative example of how sub-area temperatures are calculated.
Details on alarm events and contact information for After Sales Centre support.
Programs that can be customized: Domestic Hot Water, Elfofresh², and Zone.
Instructions on using the on-screen keyboard to name programs.
Explanation of key functions available on the program naming keyboard.
Accessing and configuring system parameters, layout, and Elfocontrol settings.
Essential warnings and procedures for installers covering regulations, installation, maintenance, and handling breakdowns.
Details on the CIECX uncased box, an optional accessory for installation.
Explanation of LED functions for connections and details on the RS485 module.
Specifications for shielded cable, serial line parameters, and installation guidelines.
Typical wiring diagrams for new buildings with radiant panels, fan coils, and radiators.
Wiring diagrams for retrofitting existing buildings with radiant panels and radiators.
Details of GAIA ARIA and ACQUA units, including models and refrigerants.
Details of the ELFOENERGY GROUND MEDIUM unit.
Details of GAIA MAXI ARIA and ACQUA units.
Details of HORUS WSAR-MT-E and WSAR-HT-E units, for indoor and outdoor installation.
Details of the ELFOENERGY EXTENDED INVERTER WSAN-XIN unit.
Details of VULCAN, GROUND, and MEDIUM units with their respective models.
Details of the ELFOFRESH² CPAN-U 70-120 unit.
Details of the ELFOFRESH² CPAN-U 200-650 unit.
Details of the ELFOFRSH LARGE CPAN-U 17-51 unit.
Details of ELFOROOM² OUTVOT and INVOT ambient terminals.
Details of ELFOSPACE OUT-V, OUT-H, IN-V, IN-H ambient terminals.
Details of ELFODUCT MP and CF-V 31-242 units.
Details of CFI, CF, ELFOSPACE BOX², and ELFOSPACEWALL² units.
Details on Elfocontrol² unit, feeder, converter, and installation accessories.
Accessories for domestic hot water control and various HID thermostat models.
Accessories for radiant panels and ambient terminals, including modules.
Description of system components like I/O modules and their communication ports.
Configuration and usage of radiant area modules with HID-T2/T3 thermostats.
Module control capabilities for valves and technical specifications.
Configuration and usage of radiant area modules with HID-TI4/UR thermostats.
Module control capabilities for valves and technical specifications.
How the Radiant Zone Module controls heated towel rail valves.
Examples of thermostat control for radiant panels and heated towel rails.
Configuring the Radiant Zone Module via thermostat, including parameters and addressing.
Configuring channels for radiant area modules, linking to thermostats and functions.
General addressing principles and specific procedures for GAIA units.
Procedure for addressing HORUS units via their interface.
Procedure for addressing WSAN-XIN units via their interface.
Procedure for addressing ELFOENERGY and ELFOFRESH² units.
Addressing terminals and areas using HID-T2/T3 thermostats and coil introduction.
Addressing terminals and areas using HID-TI2 thermostats and coil introduction.
Addressing HID-TI4/UR thermostats and troubleshooting diagnostics.
Addressing the Radiant Zone Module via selector switches or thermostats.
Addressing Mixing Modules and RS485 modules, including BT2 probe setup.
Addressing the Zone Module for heated towel rails.
Functions of I/O modules for pumps, valves, and cooling-only units.
Controlling the system remotely via telephone dial and auxiliary resource activation.
Step-by-step guide for addressing I/O modules on the bus.
Addressing and modifying parameters for the Domestic Hot Water Module.
Configuring the system via Elfocontrol², including installation composition and settings.
Steps for creating, naming, and modifying system areas using the keyboard.
Defining hydraulic circuits (mixed/non-mixed) and their combinations with boosters.
Procedure for creating a new hydraulic circuit.
Defining system components, mixed circuits, module I/O, and output functions.
Configuring outputs for circulators, area valves, seasonal control, and auxiliary resources.
Selecting Elfofresh type, combining units with areas, and defining channel components.
Assigning components to areas and defining circuit types (mixed/non-mixed).
Assigning components to areas and linking reference terminals with master terminals.
Initiating installation composition and the auto-configuration process.
Checking and confirming the successful completion of the auto-configuration procedure.
Steps to troubleshoot if 'Autoconfiguration completed' is not displayed, checking elements and network.
Verifying serial communication status between system components.
Checking the operational status of zone elements and mixing circulators.
Procedures for checking and updating the system firmware.
Inserting contact references and accessing advanced settings for system parameters.
Troubleshooting common issues related to RS485 network communication.
Guidelines for unit disposal according to WEEE directive and at authorized centers.
Parameters for GAIA units (anti-dew) and HORUS units (DHW, boiler).
Parameters for Elfo Energy, ElfoFresh², and Mixing Modules, covering various settings.
System architecture for Modbus TCP/IP and default communication parameters.
Handling communication timeouts and available command registers for plant control.
Commands for setting areas, domestic hot water, and ElfoFresh units.
Accessing read-only status information for plant parameters.
Monitoring status data for areas, domestic hot water, and ElfoFresh units.