P/N: 10001609 (REV AB) 627NH December 2014
FACTORY SETTINGS OF PARAMETERS
CONTROL PARAMETER SETTING
1 step, 2 step and 3 step
B05.01 (Acceleration Time) 3.0 Sec.
B05.02 (Deceleration Time) 3.0 Sec.
B01.01 (First Speed) 10 Hz.
B01.02 (Second Speed) over 10 Hz. thru 60 Hz.
B01.03 (Third Speed) over 10 Hz. thru 60 Hz.
A01.04 01
2 step infinitely variable
B05.01 (Acceleration Time) 3.0 Sec.
B05.02 (Deceleration Time) 3.0 Sec.
B01.01 (First Speed) 10 Hz.
B01.03 (Maximum Speed) 60 Hz.
A01.04 03
3 step infinitely variable
B05.01 (Acceleration Time) 3.0 Sec.
B05.02 (Deceleration Time) 3.0 Sec.
B01.01 (First Speed) 10 Hz.
B01.03 (Maximum Speed) 60 Hz.
A01.04 04
NOTE:
1. Standard factory setting for control is 3 Step Infinitely Variable.
2. B01.01, B05.01 and B05.02 can be accessed and changed using the user functions A02.01, A02.02 and A02.03. The other param-
eters have been factory set and pass word protected and should not be reset without authorization by EMS and/or CM.