Introduction to the built-in web interface
6-2 Chapter 6: Configuration 98-141779-G
If you want to use another LAN port to access the web interface you must configure it
as described in To configure the LAN network on page 6-24.
4. Open your Internet browser and enter the default IP address of the ACU
http://192.168.0.1.
When the login screen is displayed you have verified that the connection to the SAILOR
100 GX can be established. The web interface is ready for use.
First time login as administrator
For a new installation you must set the ACU into local administration and set the admin
password. This is also the case after a factory default. Do as follows:
1. On the ACU keypad, push and hold the left arrow key for 5 seconds.
2. Wait for the very short display of Local administration, followed by the event text:
0807F-0 WARNING Local administration enabled.
This will give you temporary administrator access for 1 hour or until next restart.
3. Open your browser and access the web interface.
4. Enter user name: admin (no password is required).
The DASHBOARD is displayed.
5. To create or change the password select ADMINISTRATION > User login and locate
the section Change Login.
Figure 6-1: LAN 3 connector used for configuration of the SAILOR 100 GX
1: Modem
3: Service port
2: User (Internet etc.)
4: Ship’s network
Figure 6-2: Logon screen
Accessing the ACU with the local administration function
does not change the current administrator password.