ComNav 1500 / 1510 Autopilot - 37 -
6.3.9 P8, Rudder Reduction Speed [RRS]
Possible settings are [0] = Minimum to [9] = Maximum.
Set by the APC routine.
The [RRS] controls the flow of the Pumpset. It will effect the
Pumpset, but not a solenoid valve steering system.
The [RRS] will be set to [5] after the APC routine is performed.
It is then possible to increase or decrease the speed reduction
of the Pumpset motor.
6.3.10 P9, Rudder angle limit [LIM]
Possible settings are [00°-99°]. Default setting is [00°].
An angle of 00° is the same as rudder angle limit disconnected
(OFF).
Note! Make sure [LIM] is set to 00° (OFF) during installation.
The rudder angle limit sets maximum angle for the rudder. If the
limit is set to 45°, it is not possible to exceed a rudder angle 45° on
either port or starboard. Check the maximum rudder angle by
turning the steering wheel to port and starboard and read the
maximum angle. If the angle is greater on one side, decrease the
smallest angle by 3°, and enter that setting as the limit.