8-7
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
POST Error Messages continued
Error Code Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
501-Display Adapter
Failure
1L,2S Video display controller Replace the video
board.
601-Diskette
Controller Error
None Diskette controller
circuitry failure
1. Make sure the
diskette drive
cables are
attached.
2. Replace the
diskette drive
and/or cable.
3. Replace the system
board.
605-Diskette Drive
Type Error
2S Mismatch in drive type Run the System
Configuration Utility to
set diskette type
correctly.
702-A coprocessor
has been detected
that was not reported
by CMOS.
None Installed coprocessor not
configured.
Run the System
Configuration Utility
and correct.
703-CMOS reports a
coprocessor that has
not been detected
2S Coprocessor or
configuration error.
1. Run the System
Configuration
Utility and correct.
2. Replace the
coprocessor.
continued

Table of Contents