8-36 Diagnostics Tools
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Table 8-2
DAAD Diagnostic Messages
Message Description Recommended Action
Accelerator board not
detected
Array controller did not
detect a configured array
accelerator board.
Install array accelerator board on array
controller. If an array accelerator board is
installed, check for proper seating on the array
controller board. You may need to run the
System Configuration Utility and disable the
array accelerator board to get this message off
the screen.
Accelerator error log List of the last 32 parity
errors on transfers to or
from memory on the array
accelerator board. Displays
starting memory address,
transfer count, and
operation (read and write).
If there are many parity errors, you may need
to replace the array accelerator board.
Accelerator parity read
errors: n
Number of times that read
memory parity errors were
detected during transfers
from memory on array
accelerator board.
If there are many parity errors, you may need
to replace the array accelerator board.
continued