DAAD Diagnostic Messages continued
Message Description Recommended Action
Board not attached Array controller configured
for use with array
accelerator board, but one
is not attached.
Attach array accelerator board to array
controller.
NVRAM configuration
present, controller not
detected
EISA nonvolatile RAM has
a configuration for an
array controller but there is
no board in this slot. Either
a board has been removed
from the system or a board
has been placed in the
wrong slot.
Place the array controller in the proper slot or
run the System Configuration Utility to
reconfigure nonvolatile RAM to reflect the
removal or new position.
Compatibility port
problem detected
Compatibility port
configured for this IDA
controller. When DAAD
was verifying this
interface, a serious
problem was detected.
A hardware problem has occurred; replace the
IDA controller.
Configuration signature
is zero
DAAD detected that
nonvolatile RAM contains a
configuration signature
that is zero. Old versions of
the System Configuration
Utility could cause this.
Run the latest version of System Configuration
Utility to configure the controller and nonvolatile
RAM.
continued