8-50 Diagnostics Tools
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages continued
Message Description Recommended Action
Drive (bay) X has loose
cable
The array controller could
not communicate with this
drive at power-up. This
drive has not previously
failed.
Check all cable connections first. The cables
could be bad, loose, or disconnected. Turn on
the system and attempt to reconnect
data/power cable to the drive. If this does not
work, replace the cable. If that does not work,
the drive may need to be replaced.
Drive (bay) X is a
replacement drive
This drive has been
replaced. This message
displays if a drive is
replaced in a fault tolerant
logical volume.
If the replacement was intentional, allow the
drive to rebuild.
Drive (bay) X is a
replacement drive
marked OK
This drive has been
replaced and marked OK
by the firmware. This may
occur if a drive has an
intermittent failure (for
example, if a drive has
previously failed, then
when DAAD is run, the
drive starts working
again).
Replace the drive.
Drive (bay) X is failed The indicated physical
drive has failed.
Replace this drive.
Drive (bay) X has
insufficient capacity for
its configuration
Drive has insufficient
capacity to be used in this
logical drive configuration.
Replace this drive with a larger capacity drive.
continued