Installation Guide for
Zone Monitor Unit
CZMU352
CZMU352 - Specification:
Installation:
Wiring Schematic:
DOC. REF.: PINSTCZMU352
Wiring
Each unit terminal connector is suitable for clamping a
single cable conductor up to a maximum of 2.5mm².
The zone monitor unit is suitable for mounting on to back
boxes with 120mm fixing centres. (surface mounting box
supplied)
General
Addressing of the unit is not required (see control panel
operation for details)
Notes:
1. Cable earth screen must be connected to its adjacent earth terminal.
2. The end of line resistor must always be fitted, even if the spur is not used.
3. Maximum spur length - see BS5839 Pt:1 2002 for zone coverage.
4. There is no maximum number of conventional call points allowed per zone output.
5. This unit can only be used with Cooper Fire Systems CDB300/I detector base and compatible detectors
18 to 30Vdc
2.8mA
3.4mA
8mA
Auto addressed
20 detectors (max)
Unlimired
-10 to +60C
0 to 95% non condensing
IP40
EN54:Pt 2 and 4
BS5839:Pt 1 (installation)
CE Marked
PC\ABS
147(w)x88(h)x57(d) mm
0.5 to 2.5mm²
Draka - FIRETUF
Pirelli - FP200
MICC
18 to 30Vdc
2.8mA
3.4mA
8mA
Auto addressed
20 detectors (max)
Unlimired
-10 to +60C
0 to 95% non condensing
IP40
EN54:Pt 2 and 4
BS5839:Pt 1 (installation)
CE Marked
PC\ABS
147(w)x88(h)x57(d) mm
0.5 to 2.5mm²
Draka - FIRETUF
Pirelli - FP200
MICC
Operating voltage:
Quiescent Current:
Current with 20 detectors
Total alarm current
Addressing mode:
Detector zone loading:
Call point load
Operating Temperature:
Humidity:
IP Rating:
Standards:
EMC:
Materials:
Dimensions:
Cable Size (Min-Max:)
Recommended Cable Types:
Operating voltage:
Quiescent Current:
Current with 20 detectors
Total alarm current
Addressing mode:
Detector zone loading:
Call point load
Operating Temperature:
Humidity:
IP Rating:
Standards:
EMC:
Materials:
Dimensions:
Cable Size (Min-Max:)
Recommended Cable Types:
1 Separate the two halves of the unit
2 Drill out the required holes for cable entries
3 Mount the back box in the required position
4 Install wiring through the pre-drilled holes
5 Connect the unit as per diagram below
6 Fit front cover
1 Separate the two halves of the unit
2 Drill out the required holes for cable entries
3 Mount the back box in the required position
4 Install wiring through the pre-drilled holes
5 Connect the unit as per diagram below
6 Fit front cover