Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 155
D.2.3: Cable Notes
1 Keep the Edge Filter to Xenus Plus cable as short as possible. A typical length is 7 inches.
2 To reduce noise, twisted shielded cable must be used and the signal cables should not be
bundled in the same conduit.
D.2.4: Edge Filter Input (J1) From Drive
Mating Connector
Euro-style, 5 position, 5.0 mm pluggable female terminal block
12 AWG, 600 V (Shielded cable used for CE compliance)
Wire Insertion/Extraction Tool
Connector and tool are included in Connector Kit XTL-FK.
Chassis ground and cable shield
Phase V input from drive (use for DC motor connection)
Phase U input from drive (use for DC motor connection)
D.2.5: Edge Filter Output (J2) To Motor
Mating Connector
Euro-style, 4 position, 5.0 mm pluggable female terminal block.
12 AWG, 600 V (Shielded cable used for CE compliance)
Wire Insertion/Extraction Tool
Connector and tool are included in Connector Kit XTL-FK.
Chassis ground and cable shield
Phase V output to motor (use for DC motor connection)
Phase U output to motor (use for DC motor connection)